* fix(ai): relax NVMe power-management workarounds and enable smartd Logs show no NVMe errors, so allow APST again (capped at 100 ms), restore the default io_timeout, and drop pcie_aspm=off. Add smartd for drive health visibility. * feat(storage): add drive/SSD SMART monitoring on physical hosts node_exporter's nvme collector only exposes node_nvme_info and namespace capacity, not SMART health, so SSD wear/lifespan and drive temperature were not observable anywhere. - enable services.prometheus.exporters.smartctl on physical hosts, gated on modules.hardwareTools (off on QEMU/MicroVM guests), bound to the host's LAN address on port 9633 - firewall: drop 9633 from anything but the monitoring host - youko: scrape smartctl-<host> for the physical hosts - alert rules (storage.yml): SMART health, NVMe wear, available spare, media errors, critical warning, and drive temperature (warn 70 / crit 80 C) - Grafana dashboard "Drive SMART (smartctl)"
58 lines
2.5 KiB
Nix
58 lines
2.5 KiB
Nix
{
|
|
config,
|
|
lib,
|
|
myvars,
|
|
...
|
|
}:
|
|
{
|
|
# enable the node exporter on all nixos hosts
|
|
# https://github.com/NixOS/nixpkgs/blob/nixos-26.05/nixos/modules/services/monitoring/prometheus/exporters/node.nix
|
|
services.prometheus.exporters.node = {
|
|
enable = true;
|
|
listenAddress = "0.0.0.0";
|
|
port = 9100;
|
|
# There're already a lot of collectors enabled by default
|
|
# https://github.com/prometheus/node_exporter?tab=readme-ov-file#enabled-by-default
|
|
enabledCollectors = [
|
|
"systemd"
|
|
"logind"
|
|
];
|
|
|
|
# use either enabledCollectors or disabledCollectors
|
|
# disabledCollectors = [];
|
|
|
|
extraFlags = [
|
|
# Exclude pseudo/ephemeral FS:
|
|
# - /proc, /sys: kernel pseudo-FS, always size 0
|
|
# - /dev: tmpfs/devices, not meaningful for disk usage
|
|
# Exclude system/runtime tmp dirs:
|
|
# - /run/credentials/... → systemd service secrets (strict perms)
|
|
# - /run/user/... → per-user tmpfs (0700, IPC sockets, not storage)
|
|
# Exclude container/runtime mounts:
|
|
# - /var/lib/docker/, /var/lib/containers/ and /var/lib/kubelet/ → too much overlay/tmpfs mounts,
|
|
# often EACCES (strict perms, namespaces) → false alerts
|
|
# Exclude user bind mounts:
|
|
# - /home/ryan/.+ → bind-mounted from /persistent (NixOS tmpfs-root setup),
|
|
# monitoring /persistent is sufficient
|
|
# Note: ^(/|/persistent/) prefix ensures both root-level and
|
|
# /persistent-prefixed paths (used in NixOS's tmpfs-as-root setup) are excluded.
|
|
"--collector.filesystem.mount-points-exclude=^(/|/persistent/)(dev|proc|sys|run/credentials/.+|run/user/.+|var/lib/docker/.+|var/lib/containers/.+|var/lib/kubelet/.+|home/ryan/.+)($|/)"
|
|
];
|
|
};
|
|
|
|
# Drive SMART health (wear, spare, media errors, temperature, bytes written)
|
|
# on physical hosts. node_exporter's nvme collector only exposes
|
|
# node_nvme_info and namespace capacity, NOT SMART health, so this is the only
|
|
# source of SSD lifespan data. `hardwareTools` is off on MicroVM/QEMU guests,
|
|
# which have no physical disks to inspect.
|
|
services.prometheus.exporters.smartctl = lib.mkIf config.modules.hardwareTools.enable {
|
|
enable = true;
|
|
# Bind to this host's LAN address rather than 0.0.0.0; the firewall also
|
|
# drops 9633 from anything but the monitoring host. Fall back to loopback
|
|
# for hosts without a static LAN address (e.g. shoukei).
|
|
listenAddress = myvars.networking.hostsAddr.${config.networking.hostName}.ipv4 or "127.0.0.1";
|
|
port = 9633;
|
|
maxInterval = "60s";
|
|
};
|
|
}
|