@@ -0,0 +1,57 @@
|
||||
groups:
|
||||
- name: general.rules
|
||||
rules:
|
||||
- alert: TargetDown
|
||||
annotations:
|
||||
description:
|
||||
'{{ printf "%.4g" $value }}% of the {{ $labels.job }}/{{ $labels.service }} targets in
|
||||
{{ $labels.namespace }} namespace are down.'
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/general/targetdown
|
||||
summary: One or more targets are unreachable.
|
||||
expr:
|
||||
100 * (count(up == 0) BY (cluster, job, namespace, service) / count(up) BY (cluster, job,
|
||||
namespace, service)) > 10
|
||||
for: 10m
|
||||
labels:
|
||||
severity: warning
|
||||
- alert: Watchdog
|
||||
annotations:
|
||||
description: 'This is an alert meant to ensure that the entire alerting pipeline is
|
||||
functional.
|
||||
|
||||
This alert is always firing, therefore it should always be firing in Alertmanager
|
||||
|
||||
and always fire against a receiver. There are integrations with various notification
|
||||
|
||||
mechanisms that send a notification when this alert is not firing. For example the
|
||||
|
||||
"DeadMansSnitch" integration in PagerDuty.'
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/general/watchdog
|
||||
summary:
|
||||
An alert that should always be firing to certify that Alertmanager is working properly.
|
||||
expr: vector(1)
|
||||
labels:
|
||||
severity: none
|
||||
- alert: InfoInhibitor
|
||||
annotations:
|
||||
description: 'This is an alert that is used to inhibit info alerts.
|
||||
|
||||
By themselves, the info-level alerts are sometimes very noisy, but they are relevant
|
||||
when combined with
|
||||
|
||||
other alerts.
|
||||
|
||||
This alert fires whenever there''s a severity="info" alert, and stops firing when
|
||||
another alert with a
|
||||
|
||||
severity of ''warning'' or ''critical'' starts firing on the same namespace.
|
||||
|
||||
This alert should be routed to a null receiver and configured to inhibit alerts with
|
||||
severity="info".'
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/general/infoinhibitor
|
||||
summary: Info-level alert inhibition.
|
||||
expr:
|
||||
ALERTS{severity = "info"} == 1 unless on(namespace) ALERTS{alertname != "InfoInhibitor",
|
||||
severity =~ "warning|critical", alertstate="firing"} == 1
|
||||
labels:
|
||||
severity: none
|
||||
Reference in New Issue