Insert SFP Module in Interface #6595

Closed
opened 2025-12-29 19:42:47 +01:00 by adam · 2 comments
Owner

Originally created by @adarshharisree on GitHub (Jun 24, 2022).

NetBox version

v3.2.4

Feature type

New functionality

Proposed functionality

It will be beneficial to have an option to add SFP module details add to the switch, router or server interfaces. Most of the device's interfaces are SFP or SFP+. Currently, we are mentioning the interface type modular but are not able to mention which type of SFP is inserted.

We are currently connecting the SPF+ Port to the front-rear or to another device.

  1. Simplex or Duplex
  2. WaveLength
  3. WDM/DWDM/CWDM
  4. 1G or 10G
  5. Connector Type : LC or SC
  6. Multimode or Singlemode

As part of inventory, we can add the serial number of each SFP Modules,

Use case

Based on the SFP Module the connection between interface and front port may change

  1. For Duplex SFP+ we need 1:2 mapping for interface to front-port
  2. For Simplex SFP+ we need 1:1 mapping for interface to front-port
  3. Inventory data of all used SFP Modules

Database changes

  1. Additional Colum to add the inserted SFP module details in the Interface table
  2. Additional table to list down the SFP module characteristics.

External dependencies

No response

Originally created by @adarshharisree on GitHub (Jun 24, 2022). ### NetBox version v3.2.4 ### Feature type New functionality ### Proposed functionality It will be beneficial to have an option to add SFP module details add to the switch, router or server interfaces. Most of the device's interfaces are SFP or SFP+. Currently, we are mentioning the interface type modular but are not able to mention which type of SFP is inserted. We are currently connecting the SPF+ Port to the front-rear or to another device. 1. Simplex or Duplex 2. WaveLength 3. WDM/DWDM/CWDM 4. 1G or 10G 5. Connector Type : LC or SC 6. Multimode or Singlemode As part of inventory, we can add the serial number of each SFP Modules, ### Use case Based on the SFP Module the connection between interface and front port may change 1. For Duplex SFP+ we need 1:2 mapping for interface to front-port 2. For Simplex SFP+ we need 1:1 mapping for interface to front-port 3. Inventory data of all used SFP Modules ### Database changes 1. Additional Colum to add the inserted SFP module details in the **Interface table** 2. Additional table to list down the SFP module characteristics. ### External dependencies _No response_
adam added the type: feature label 2025-12-29 19:42:47 +01:00
adam closed this issue 2025-12-29 19:42:48 +01:00
Author
Owner
@adamboutcher commented on GitHub (Jun 24, 2022): See: https://github.com/netbox-community/netbox/issues/8980 https://github.com/netbox-community/netbox/issues/9377
Author
Owner

@jeremystretch commented on GitHub (Jun 24, 2022):

This has already been discussed numerous times; please see the other issues and discussions here on GitHub. SFPs should be modeled as inventory items, and can be assigned to individual components in NetBox v3.2 or later.

@jeremystretch commented on GitHub (Jun 24, 2022): This has already been discussed numerous times; please see the other issues and discussions here on GitHub. SFPs should be modeled as inventory items, and can be assigned to individual components in NetBox v3.2 or later.